66 / 110KV XLPE Insulated Corrugated Aluminum And PE Sheathed Underground Cables
Quick Detail
Insulation Material |
XLPE |
Type |
High Voltage |
Application |
Underground |
Conductor Material |
Copper |
Jacket |
PVC |
Character |
waterblock |
Description
XLPE-insulated power cables for rated voltage 110kV should perform the rules of XLPE-insulated
Power Cable for Cable for Rated Voltage 110kV and its attachments in GB/T 11017-2002, which
is equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 30kV
up to 150kV in IEC 60840:1999.
XLPE-insulated power cables for rated voltage 220kV should perform the rules of XLPE-insulated
Power Cable for Cable for Rated Voltage 220kV and its attachments in GB/T 18890-2002, which is
equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage 150kV
up to 500kV in IEC 62067:2001.
XLPE-insulated power cables for rated voltage 500kV should perform the rules of XLPE-insulated
Power Cable for Cable for Rated Voltage 220kV and its attachments in GB/T 22078-2008, which is
equal to The Test Methods and Requirements of Extruded Insulation Power Cables for Voltage
150kV up to 500kV in IEC 62067:2006.
XLPE-insulated power cables for rated voltage 66kV should perform The Test Methods and
Requirements of Extruded Insulation Power Cables for Voltage 30kV up to 150kV in IEC 60840:1999.
Main Performance
1. The rated voltage U0/U of cables:38/66kV, 48/66kV, max. voltage Um=72.5kV;
64/110kV, max. voltage Um=126kV;
127/220kV, max voltage Um=252kV;
290/500kV, max voltage Um=550kV;
2. permissible long-term working temperature of cable conductor:90;
3. When the cable confronts short circuit within 5 seconds, the highest temperature of conductor
should not exceed 250. When there exits line joints, the temperature of tin soldering ones should
not exceed 120, the temperature of crimping ones should not exceed 150, and the temperature
of electric or gas welding should not exceed 250
4. When laying, the permissible bending radius should exceed 25 times of the out diameter of the cables.
After laying, the permissible bending radius should exceed 23 times of the out diameter of the cables.
1. When laying, ambient temperature≥0(when the cable has to be laid under the ambient temperature